Banglalink Alliance Computers Limited

Site HOTO Report β€” SYL_X0075

Project Tiger · Dhaly Infratech → Alliance Computers Limited · Generated 07-Sep-2026 20:21 BD time
73%Form Completion 15/15Checklist OK 0Open Snags 0Total Snags 18Photos Attached
Incomplete: the following expected fields were left blank in this submission β€” Site Type, BTS Type, Site Sharing.

Site & Handover Details

Site CodeSYL_X0075ZoneSylhet
HOTO Date2026-09-02DistrictMoulavibazar
Handover OrgDhaly InfratechTakeover OrgAlliance Computers Limited
Handover PersonSayedTakeover PersonSourav
Handover Phone01716332171Takeover Phone01847426870
Inspected Bysourov sarkarSecurity GuardYes
Access Key Handed OverSite TypeNot Filled
BTS TypeNot Filled
Shared with OperatorNot FilledShared Operator Name

Generator Information

DG BrandTempestGenset Asset No.
Capacity (KVA)22TypeCan
Fuel Tank Capacity2000Present RH4181
Fuel (no water)230 LFuel (total)230 L
Water Amount00 LFuel Amount (word)Two Hundred Thirty Liters
DG Site TypeStandardDG Locked After FuelingYes
DG Present StatusOK Genset ON AlarmOK
Battery BrandHamkoBattery SerialP033WMC60124
Battery AH100Engine SerialM84582216m533CK
ATS BrandLocalATS ModeAuto
RH Meter TypeDigital from controllerLast Service Date2026-07-23
Key TypeLocal KeyKey Status β€” BTS
Key Status β€” DG Room
Active DG1Connected Fuel Tanks1
Faulty/Disconnected DGFaulty/Disconnected Tanks

Connected Generator Checklist & Readings

ItemValueItemValue
Earth Connection OKYesLoad Current (A)24
Frequency (Hz)52.4Phase3 Phase
Output24Voltage L1-L2390
Voltage L2-L3395Voltage L3-L1390
Voltage L1-N210Voltage L2-N220
Voltage L3-N215Current Line 18
Current Line 28Current Line 38
Engine BrandPerkins Controller StatusOK
Black Smoke StatusOKDG Battery ChargerOK
ATS Physical & Functional StatusOKDG Automation (VDTC/RVDTC/Rectifier) per BL StandardOK
Fuel Preserved at Safe & Appropriate LocationOKExhaust Fan / Ventilation Sufficient When RunningOK
Sufficient Water in Radiator & BatteryOKDG Radiator ConditionOK
DG Battery ConditionOKDG Runs in Both Auto & Manual ModeOK
GENSET ON Alarm Functioning ProperlyOKLub Oil Status (Level & Colour)OK
DG RH Meter Working ProperlyOKNo Parts Missing (if missing, note in snags below)OK

Snags Found (0)

No snags logged for this visit.

Deficiencies & Safety Remarks

DG Major DeficienciesDG room light faulty
Safety Remarks
General Remarks

Site Photos


Site / Nameplate

DG RH / Meter

Fuel Gauge

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional
Sayed
Handed Over By · Dhaly Infratech
01716332171
Date:  
Sourav
Taken Over By · Alliance Computers Limited
01847426870
Date:  
 
BL Concern · Name / Signature
 
Date:  

Appendix β€” Photo Evidence (18)

Full-size reference photos for SYL_X0075, grouped by type and numbered for cross-reference against the tables above.

Required Site Photos (3)

Photo 1 β€” Site / Nameplate
Photo 2 β€” DG RH / Meter
Photo 3 β€” Fuel Gauge

Additional Photos (15)

Photo 4 β€” Site Context 1
Photo 5 β€” Site Context 2
Photo 6 β€” Site Context 3
Photo 7 β€” Site Context 4
Photo 8 β€” Site Context 5
Photo 9 β€” Site Context 6
Photo 10 β€” Site Context 7
Photo 11 β€” Site Context 8
Photo 12 β€” Site Context 9
Photo 13 β€” Site Context 10
Photo 14 β€” Site Context 11
Photo 15 β€” Site Context 12
Photo 16 β€” Site Context 13
Photo 17 β€” Site Context 14
Photo 18 β€” Site Context 15

Download / Print PDFEdit Before Printing