Banglalink Alliance Computers Limited

Site HOTO Report β€” SYL_X0364

Project Tiger · Dhaly Infratech → Alliance Computers Limited · Generated 25-Oct-2026 20:26 BD time
73%Form Completion 15/15Checklist OK 5Open Snags 5Total Snags 23Photos Attached
Incomplete: the following expected fields were left blank in this submission β€” Site Type, BTS Type, Site Sharing.

Site & Handover Details

Site CodeSYL_X0364ZoneSylhet
HOTO Date2026-09-03DistrictMoulavibazar
Handover OrgDhaly InfratechTakeover OrgAlliance Computers Limited
Handover PersonOmar FarukTakeover PersonSourav
Handover Phone01406394566Takeover Phone01847426870
Inspected Bysourov sarkarSecurity GuardYes
Access Key Handed Over—Site TypeNot Filled
BTS TypeNot Filled
Shared with OperatorNot FilledShared Operator Name—

Generator Information

DG BrandFG WilsonGenset Asset No.No
Capacity (KVA)30TypeCan
Fuel Tank Capacity2000Present RH146.4
Fuel (no water)394 LFuel (total)394 L
Water Amount00 LFuel Amount (word)Three Hundred Ninety Four Liters
DG Site TypeStandardDG Locked After FuelingYes
DG Present StatusOK Genset ON AlarmOK
Battery BrandVolvoBattery Serial05BB0325
Battery AH100Engine SerialDJ32015
ATS BrandLocalATS ModeAuto
RH Meter TypeDigital from controllerLast Service Date2026-07-28
Key TypeLocal KeyKey Status β€” BTSLocal
Key Status β€” DG RoomLocal
Active DG1Connected Fuel Tanks1
Faulty/Disconnected DG0Faulty/Disconnected Tanks0

Connected Generator Checklist & Readings

ItemValueItemValue
Earth Connection OKYesLoad Current (A)23
Frequency (Hz)50.3Phase3 Phase
Output23Voltage L1-L2390
Voltage L2-L3395Voltage L3-L1389
Voltage L1-N210Voltage L2-N205
Voltage L3-N212Current Line 18
Current Line 27Current Line 38
Engine BrandPerkins Controller StatusOK
Black Smoke StatusOKDG Battery ChargerOK
ATS Physical & Functional StatusOKDG Automation (VDTC/RVDTC/Rectifier) per BL StandardOK
Fuel Preserved at Safe & Appropriate LocationOKExhaust Fan / Ventilation Sufficient When RunningOK
Sufficient Water in Radiator & BatteryOKDG Radiator ConditionOK
DG Battery ConditionOKDG Runs in Both Auto & Manual ModeOK
GENSET ON Alarm Functioning ProperlyOKLub Oil Status (Level & Colour)OK
DG RH Meter Working ProperlyOKNo Parts Missing (if missing, note in snags below)OK

Snags Found (5)

Snag #SystemCategoryComponentStatusObservationsActionPhoto
S-162 General — DG Fuel Pipe Faulty Fuel pipe hard (from paper HOTO checklist PDF, transcribed 2026-09-16) Open —
S-163 General — Hi-Temp Sensor Faulty Hi-temp sensor faulty (preceding phrase 'need to fuel tank' crossed out/cancelled) (from paper HOTO checklist PDF, transcribed 2026-09-16) Open —
S-164 General — DG Controller Faulty Not fixed, needs to be fixed properly (from paper HOTO checklist PDF, transcribed 2026-09-16) Open —
S-165 General — DG Room Light Not Available Written as faulty then struck through/cancelled -- likely resolved or entered in error, treat with caution (from paper HOTO checklist PDF, transcribed 2026-09-16) Open —
S-166 General — Phase (electrical) Faulty 1 phase missing (from paper HOTO checklist PDF, transcribed 2026-09-16) Open —

Deficiencies & Safety Remarks

DG Major DeficienciesDG fuel pipe hard; Hi-temp sensor faulty (a crossed-out 'need to fuel tank' note preceded it); DG controller not fixed, needs to be fixed properly; DG room light faulty (struck through/cancelled); 1 phase missing
Safety RemarksDG fuel pipe hard; Hi-temp sensor faulty; DG controller not fixed, needs to be fixed properly; 1 phase missing
General RemarksPDF checklist notes: Genset Asset No field literally handwritten as 'NO' (may mean 'none/not assigned' rather than a value). Engine serial handwriting dense and partly overlapped, transcription is best-effort -- verify against original. Below the main signature block, two additional numbered notes ((iii)/(iv) style) appear outside the boxed form area: 'DG room light faulty' (struck through) and '1 phase missing' -- included as snags but flagged since one is cancelled by the writer. Site already has a real DB record per task context; this is a supplemental/cross-check extraction.

Site Photos


Site / Nameplate

DG RH / Meter

Fuel Gauge

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional
Omar Faruk
Handed Over By · Dhaly Infratech
01406394566
Date:  
Sourav
Taken Over By · Alliance Computers Limited
01847426870
Date:  
 
BL Concern · Name / Signature
 
Date:  

Appendix β€” Photo Evidence (23)

Full-size reference photos for SYL_X0364, grouped by type and numbered for cross-reference against the tables above.

Required Site Photos (3)

Photo 1 β€” Site / Nameplate
Photo 2 β€” DG RH / Meter
Photo 3 β€” Fuel Gauge

Additional Photos (20)

Photo 4 β€” Additional Photos 1
Photo 5 β€” Additional Photos 2
Photo 6 β€” Additional Photos 3
Photo 7 β€” Additional Photos 4
Photo 8 β€” Additional Photos 5
Photo 9 β€” Additional Photos 6
Photo 10 β€” Additional Photos 7
Photo 11 β€” Additional Photos 8
Photo 12 β€” Additional Photos 9
Photo 13 β€” Additional Photos 10
Photo 14 β€” Additional Photos 11
Photo 15 β€” Additional Photos 12
Photo 16 β€” Additional Photos 13
Photo 17 β€” Additional Photos 14
Photo 18 β€” Additional Photos 15
Photo 19 β€” Additional Photos 16
Photo 20 β€” Additional Photos 17
Photo 21 β€” Additional Photos 18
Photo 22 β€” Additional Photos 19
Photo 23 β€” Additional Photos 20

Download / Print PDFEdit Before Printing