Site & Handover Details

Site CodeDHK_X4606ZoneSylhet
HOTO Date2026-09-03DistrictKishoreganj
Handover OrgDhaly InfratechTakeover OrgAlliance Computers Limited
Handover PersonSree Bishwajeeet KumarTakeover PersonMd Kobir Hossain
Handover Phone018509550252Takeover Phone01958313020
Inspected BySojib HossanSecurity GuardNo
Access Key Handed OverSite TypeGF-RT
BTS TypeOutdoor
Shared with OperatorNot FilledShared Operator Name

Generator Information

DG BrandWelland PowerGenset Asset No.
Capacity (KVA)22Type
Fuel Tank Capacity2000Present RH2089
Fuel (no water)244 LFuel (total)270 L
Water Amount26 LFuel Amount (word)Two Hundred Seventy Liters
DG Site TypeDG Locked After FuelingYes
DG Present StatusOK Genset ON AlarmOK
Battery BrandHamkoBattery SerialPO33WLAG0107
Battery AHEngine SerialUK255709001977
ATS BrandNaradaATS ModeAuto
RH Meter TypeLast Service Date
Key TypeLocal KeyKey Status β€” BTS
Key Status β€” DG RoomLocal
Active DG1Connected Fuel Tanks1
Faulty/Disconnected DG1Faulty/Disconnected Tanks1

Connected Generator Checklist & Readings

ItemValueItemValue
Phase3 PhaseVoltage L1-N232
Voltage L2-N234Voltage L3-N229
Engine BrandParkingController StatusOK
Black Smoke StatusOKDG Battery ChargerOK
ATS Physical & Functional StatusOKDG Automation (VDTC/RVDTC/Rectifier) per BL StandardOK
Fuel Preserved at Safe & Appropriate LocationOKExhaust Fan / Ventilation Sufficient When RunningOK
Sufficient Water in Radiator & BatteryOKDG Radiator ConditionOK
DG Battery ConditionOKDG Runs in Both Auto & Manual ModeOK
GENSET ON Alarm Functioning ProperlyOKLub Oil Status (Level & Colour)OK
DG RH Meter Working ProperlyOKNo Parts Missing (if missing, note in snags below)OK

Snags Found (0)

No snags logged for this visit.

Deficiencies & Safety Remarks

DG Major Deficiencies1,DG Open Space
Safety Remarks
General Remarks

Site Photos


Site / Nameplate

DG RH / Meter

Fuel Gauge

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional

Additional
Sree Bishwajeeet Kumar
Handed Over By · Dhaly Infratech
018509550252
Date:  
Md Kobir Hossain
Taken Over By · Alliance Computers Limited
01958313020
Date:  
 
BL Concern · Name / Signature
 
Date:  

Appendix β€” Photo Evidence (17)

Full-size reference photos for DHK_X4606, grouped by type and numbered for cross-reference against the tables above.

Required Site Photos (3)

Photo 1 β€” Site / Nameplate
Photo 2 β€” DG RH / Meter
Photo 3 β€” Fuel Gauge

Additional Photos (14)

Photo 4 β€” Site Context 1
Photo 5 β€” Site Context 2
Photo 6 β€” Site Context 3
Photo 7 β€” Site Context 4
Photo 8 β€” Site Context 5
Photo 9 β€” Site Context 6
Photo 10 β€” Site Context 7
Photo 11 β€” Site Context 8
Photo 12 β€” Site Context 9
Photo 13 β€” Site Context 10
Photo 14 β€” Site Context 11
Photo 15 β€” Site Context 12
Photo 16 β€” Site Context 13
Photo 17 β€” Site Context 14

Download / Print PDFEdit Before Printing